Cell Culture Bags

CellStor® Cell Culture Bags

CellStor® Cell Culture Bags are used to expand and differentiate suspension cells (primary cells and cell lines). The CellStor Cell Culture Bag’s unique design frame aids in batch and continuous culture. The needle-free port makes sampling much easier.

CellStor Cell Culture Bags are made up of special grade transparent Ethylene-vinyl acetate (EVA).

Closed system for contaminant free culture by multiple connectivity for media preparation, addition and passaging.

CellStor Cell Culture Bags are a single-use, easy-to-handle suspension cell/non-adherent cell culture device used in biotech and pharma industries and research facilities. It is used for cell growth, expansion, and differentiation (primary cells and cell lines).

CellStor Cell Culture Bags are custom-made for Expansion and Differentiation individually in a variety of volumes. The film allows maximum gas exchange (O2 and CO2) making it suitable for cell growth in a confined environment.

CellStor® Cell Culture Bags for biotech and biopharma industries

CellBios closed cell culture system can be used for various cell culture activities involving hematopoietic cell lineages (eg. CAR-T & CAR-NK Cell Therapies, Hematopoietic Cell Differentiation, etc.) This system will be useful to all the Biotech & Biopharma industries, academic institutions and other R&D institutions which handles in-vitro cell culture activities.

Features

  • Easy sampling

  • Sterile, individually packed

  • A closed system avoids contamination

  • Filter to facilitate batch and continuous culture

  • Non-reactive with cells and buffer system

  • Increased Gas permeability

  • Easily scalable and fit for Invitro experiments

  • The unique internal design helps in complete volume transfer

  • High-density cell yield in mass cell culture

  • Safe and easy to process

  • The film transparency makes microscopy easier

CellBios cell culture system offers a closed condition for media filling, addition of growth factors, antibiotics to ensure microbial free environment.

Cell Culture Bags – Recommended Working Volume

CatalogueMinimum Working
Volume (mL)
Cell Seeding
Density per (mL)
Maximum Working
Volume (mL)
Cell Yield
per (mL)
CCEE03-010.60.75* 10^61.83* 10^6
CCDE03-010.60.75* 10^61.83* 10^6
CCEE07-011.40.75* 10^64.23* 10^6
CCDE07-011.40.75* 10^64.23* 10^6
CCEE15-013.00.75* 10^69.03* 10^6
CCDE15-013.00.75* 10^69.03* 10^6
CCEE25-019.60.75* 10^6193* 10^6
CCDE25-019.60.75* 10^6193* 10^6
CCEE50-01150.75* 10^6313* 10^6
CCDE50-01150.75* 10^6313* 10^6
CCEE100-01380.75* 10^6773* 10^6
CCDE100-01380.75* 10^6773* 10^6
CCEE200-01620.75* 10^61243* 10^6
CCDE200-01620.75* 10^61243* 10^6
CCEE500-011760.75* 10^63023* 10^6
CCDE500-011760.75* 10^63023* 10^6
CCEE1000-012700.75* 10^66173* 10^6
CCDE1000-012700.75* 10^66173* 10^6
CCEE2000-014710.75* 10^613463* 10^6
CCDE2000-0147110.75* 10^613463* 10^6
CCEE3000-016500.75* 10^620433* 10^6
CCDE3000-016500.75* 10^620433* 10^6
CCEE5000-0110420.75* 10^635683* 10^6
CCDE5000-0110420.75* 10^635683* 10^6

Closed Cell Culture Bags for Cell Expansion

CellStor® Closed Cell Culture Expansion Systems are made for growing and expanding hematopoietic cells and the sub-lineages/ anchorage in-dependent cells. The flexible volumes from 3 mL to 5000 mL provides wide range of choices for experimental needs. transparent and microscopic compatible.

Cell Expansion

Ordering Information – Cell Expansion Bags

Part NumberDescriptionPackaging
CCEE03-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE07-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE15-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE25-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE50-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE100-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE200-01Port(3), EVA tubing (3x4.1 mm) IDxOD with one female luer and needle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE500-01Port(3), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer andneedle free for top area and one female luer (Outlet) for bottom area.24 /case
CCEE1000-01Port(3), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer andneedle free for top area and one female luer (Outlet) for bottom area.12 /case
CCEE2000-01Port(3), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer andneedle free for top area and one female luer (Outlet) for bottom area.12 /case
CCEE3000-01Port(3), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer andneedle free for top area and one female luer (Outlet) for bottom area.12 /case
CCEE5000-01Port(3), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer andneedle free for top area and one female luer (Outlet) for bottom area.12 /case

Closed Cell Culture Bags for Cell Differentiation

CellStor® Closed Cell Culture Differentiation Systems are made for differentiating hematopoietic cells and the sub-lineages/anchorage in-dependent/ Suspension cells. The flexible volumes from 3 mL to 5000 mL provides wide range of choices for experimental needs. transparent and microscopic compatible.

Cell Differentiation

Ordering Information – Cell Differentiation Bags

Part NumberDescriptionPackaging
CCDE03-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE07-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE15-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE25-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE50-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE100-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE200-01Ports(2), EVA tubing (3x4.1 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE500-01Ports(2), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet24 /case
CCDE1000-01Ports(2), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet12 /case
CCDE2000-01Ports(2), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet12 /case
CCDE3000-01Ports(2), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet12 /case
CCDE5000-01Ports(2), EVA tubing (3x4.1 / 3.2x6.4 mm) IDxOD with one female luer for inlet (needle free) and one female lure for outlet12 /case